Fire Protection Systems

Fire Detection and Alarm Systems (Fire Alarm Systems)

Life-safety infrastructure that detects smoke and heat early, warns occupants and triggers other systems: discovery, installation, commissioning and maintenance.

In short

A fire detection and alarm system (fire alarm system) is a life-safety system that detects smoke, heat or flame early, warns occupants with sounders and beacons, and triggers systems such as doors, lifts and voice evacuation when needed. Sora Yazılım provides discovery, installation, commissioning and periodic maintenance for these systems in İzmir and its surroundings.

What is a fire detection and alarm system and what does it do?

A fire detection and alarm system is installed to detect a fire at the earliest possible stage, warn people and buy time for evacuation; it does not extinguish the fire, but it sets suppression and evacuation systems in motion on time.

At the centre of the system is the fire alarm panel (control and indicating equipment). Detectors and manual call points report to the panel; the panel activates sounders and beacons, shows where the alarm came from and runs the cause-and-effect scenarios defined in the design.

In areas such as data centres, high-ceiling warehouses or clean rooms, systems that continuously sample the air can give an earlier warning; this specialist use is the subject of our aspirating smoke detection (ASD) systems page. Despite the similar name, gas detection systems detect flammable or toxic gas leaks rather than fire; both can be present in the same building.

Fire alarm system flow diagram: detectors and manual call points, fire alarm panel, sounders, beacons and triggered systems
Devices signal the panel; the panel activates sounders and beacons and triggers the outputs defined in the design.

Which buildings need a fire detection system?

For projects in Türkiye, whether a building must have a fire detection system is set by the Regulation on the Protection of Buildings from Fire according to its use, height and occupancy; this is assessed at design stage by a qualified design engineer and the relevant authority.

Where it is not mandatory, the system is still chosen for life and property safety, especially in areas used at night, used for storage or occupied by many people. The buildings we come across most often are:

  • Office floors and office towers, meeting and training areas.
  • Factories, workshops and warehouses; high-ceiling storage areas.
  • Accommodation such as hotels, guesthouses and student residences.
  • Schools, training centres and healthcare facilities.
  • Technical spaces such as comms rooms, archives and electrical rooms.
  • Common areas of residential complexes, car parks and retail units.

What types of fire alarm system are there and what are the components?

Fire alarm systems fall into two main types, conventional and addressable: a conventional system shows which zone the alarm came from, while an addressable system shows which device it came from.

Conventional and addressable fire alarm systems compared
FeatureConventional systemAddressable system
Alarm locationZone levelIndividual device level
Wiring layoutA separate circuit for each zoneDevices share the same loop circuit
Fault findingThe faulty zone is identified, then the device is searched forThe faulty device is shown directly
Scenario flexibilityLimited, zone-basedDetailed, by device and by zone
Typical useSmall areas with few zonesLarge, multi-storey or multi-zone buildings

Which type suits a building is decided in the design according to its size, number of zones, likelihood of future expansion and integration needs. The main components of the system are:

  • Control and indicating equipment (fire panel): shows alarms and faults and manages the scenarios.
  • Smoke detector: detects smoke in the early stage of a fire.
  • Heat detector: responds to a rise in temperature in areas where smoke or dust is normal.
  • Flame detector: detects flame radiation in open areas and large volumes.
  • Manual call point: lets the person who sees a fire raise the alarm by hand.
  • Sounders and beacons: give audible and visual warning.
  • Power supply and batteries: keep the system running when mains power fails.

What does our fire detection service scope include?

The service scope runs from discovery to periodic maintenance; where the design must be prepared by a qualified design engineer and approved by the relevant authority, installation follows the approved design.

  • Discovery: reviewing how the building is used, its zones, the existing system and any existing fire design.
  • Device and panel selection to the design, bill of materials and procurement.
  • Cabling and device mounting (cable type and route according to the design).
  • Panel programming: zone and device definitions, alarm and fault messages.
  • Cause-and-effect set-up: outputs to sounders, beacons and the other systems defined in the design.
  • Commissioning and functional testing; handover of test records.
  • User training for building staff.
  • Periodic maintenance and testing (under contract).

Preparing and approving the fire design is the responsibility of the qualified engineer and the relevant authority. This page provides general information; decisions specific to your building are based on the approved design.

How does a fire detection project run?

The process starts with discovery, continues with installation and testing to the approved design, and carries on with periodic maintenance once the system has been handed over with user training.

  1. Discovery call: we discuss the building, its use and the current situation.
  2. Site survey: zones, ceiling heights, cable routes and existing devices are inspected.
  3. Design: an existing approved design is reviewed; if there is none, its preparation with a qualified design engineer is planned.
  4. Proposal: the device list, scope and work schedule are set out.
  5. Installation: cabling, mounting and panel connections are completed.
  6. Commissioning and testing: every device and scenario is tested and the results are recorded.
  7. Training and handover: panel operation and what to do during an alarm are explained.
  8. Periodic maintenance: tests and maintenance records are kept up regularly.

Which factors affect the choice and the cost?

The cost of a fire detection system depends mainly on the size of the area, the number of zones and devices, the panel type and integration needs; an exact figure comes after discovery and design.

We do not publish price ranges; two buildings of the same size can have very different needs depending on their use and the approved design.

  • Total floor area, number of storeys and number of separate zones.
  • Choice of conventional or addressable panel and future expansion needs.
  • Detector types (smoke, heat, flame) and device count.
  • Cable routes, ceiling height and any need to work at height.
  • Integration with lifts, ventilation, doors and voice evacuation.
  • The state of the existing system: upgrade or new installation.

Which standards and regulations apply?

For projects in Türkiye, the core rules on protecting buildings from fire are set by the Regulation on the Protection of Buildings from Fire; in Europe, the EN 54 series of standards is used for fire detection and fire alarm system components.

Values such as detector positions, spacing between devices and the number of zones are calculated for each building; the relevant standard and a qualified design engineer are the reference. The information on this page does not replace a design.

  • Regulation on the Protection of Buildings from Fire (Binaların Yangından Korunması Hakkında Yönetmelik, Official Gazette 19.12.2007, No. 26735, as amended). The current text should be checked on mevzuat.gov.tr.
  • EN 54-2 — control and indicating equipment (fire panel).
  • EN 54-4 — power supply equipment.
  • EN 54-5 and EN 54-7 — point heat and smoke detectors.
  • EN 54-11 — manual call points.
  • EN 54-3 and EN 54-23 — audible and visual alarm devices.

How does a fire detection system integrate with other systems?

During an alarm, the fire panel signals the systems defined in the design; the aim is to make evacuation safer and easier and to limit the spread of the fire.

Which outputs are used, and in what order, is specific to each building; every scenario should be tested one by one at commissioning. For the overall picture of other fire systems, see our fire protection systems page.

Which questions do we ask during discovery?

The right system starts with understanding how the building is used; during discovery we work through the following questions together.

  • What is the building used for; are there areas used at night or crowded areas?
  • Is there an approved fire design, and when was it last updated?
  • Where are the areas, such as kitchens, boiler rooms or car parks, in which a smoke detector could cause false alarms?
  • Which systems need integration: doors, lifts, ventilation, voice evacuation?
  • If there is an existing system, where are the latest maintenance and test records?
  • Who will monitor the panel during an alarm, and who should be notified?

What are the common mistakes with fire detection systems?

The most frequent problems come from the wrong choice of device, layouts that are not updated and maintenance that is not recorded.

  • Putting smoke detectors everywhere: false alarms in kitchens and dusty areas erode users' trust in the system.
  • Not updating the layout after refurbishment: new partition walls change the area a detector covers.
  • Not testing the scenarios: door, lift and voice evacuation outputs are only reliable once they have been tested.
  • Permanently silencing fault warnings: a pending fault on the panel can mean a zone that will not work in a real alarm.
  • Not keeping maintenance records: nobody knows which device was tested and when.

Related services

Frequently asked questions

Should I choose a conventional or an addressable fire alarm panel?
In small areas with few zones, a conventional system may be enough. In multi-storey or multi-zone buildings, or those likely to grow, an addressable system makes response and maintenance easier because it shows which device an alarm or fault came from. The decision is made according to the building's size, integration needs and the approved design.
Which buildings must have a fire alarm system?
For projects in Türkiye, the requirement depends on the building's use, height and occupancy and is set by the Regulation on the Protection of Buildings from Fire. Whether it applies to your building, and the scope of the system, is assessed by a qualified design engineer and the relevant authority. We can review your existing design and documents together, and the assessment should be repeated after any refurbishment.
Can a fire detection system be added to an existing building?
Yes. In occupied buildings, cable routes are planned around existing ceilings, trunking and risers, and the work is done section by section. In addressable systems, the loop layout can reduce the amount of cable needed in a retrofit. Before installation, the building's approved design and the condition of existing devices are reviewed. The work schedule is agreed during discovery around the building's hours of use.
How often should a fire detection system be maintained?
Maintenance and test intervals are set according to the relevant standards, manufacturer instructions and regulations, and should be written into the contract. What matters is that every device is tested regularly and the results are recorded. Faults showing on the panel should be fixed without waiting for the next visit. After maintenance, always check that the panel has returned to normal.
How can false alarms be prevented?
Most false alarms are caused by detectors unsuited to the area, dirty devices and detectors left exposed during building work. Choosing the right detector type for areas such as kitchens, regular cleaning and maintenance, and taking controlled precautions before refurbishment reduce the problem significantly. The cause of every false alarm should be recorded so that recurring problems can be traced.
How does the discovery call work?
First, in a short call, we discuss how the building is used, its zones and any existing system or approved design. A site survey follows if needed. The call is free and involves no commitment. To arrange it, use the request form on this page or give us a call. If you can share the existing design and maintenance records, the conversation will be more productive.
Which areas do you cover for fire detection systems?
We provide on-site installation and maintenance in İzmir and its surroundings: İzmir districts such as Menemen and Selçuk, plus Manisa and Aydın. For a building outside this area, we first discuss your request in a discovery call and confirm together whether the scope is a fit. Because the first conversation can take place by phone or online, that step does not depend on location.

Sources

Request form

Fire detection and alarm request

Including the building type, approximate floor area, number of storeys and whether there is an existing system speeds up the first conversation.

Free discovery call
No commitment; the quote is prepared after the survey.
Service area
İzmir and its surroundings (districts such as Menemen and Selçuk, plus Manisa and Aydın)
Your personal data
Form details are processed to answer your request; see the privacy notice for details. Privacy notice
24 saat içinde geri dönüş yaparız.

Let us talk about your fire detection system

For a new installation, upgrade or maintenance, tell us about your building and its current state, and we will start the discovery process together.

WhatsApp Support